| struct_regulator_ops(9) - phpMan
STRUCT REGULATOR_OPS(9) API reference STRUCT REGULATOR_OPS(9)
NAME
struct_regulator_ops - regulator operations.
SYNOPSIS
struct regulator_ops {
int (* list_voltage) (struct regulator_dev *, unsigned selector);
int (* set_voltage) (struct regulator_dev *, int min_uV, int max_uV,unsigned *selector);
int (* map_voltage) (struct regulator_dev *, int min_uV, int max_uV);
int (* set_voltage_sel) (struct regulator_dev *, unsigned selector);
int (* get_voltage) (struct regulator_dev *);
int (* get_voltage_sel) (struct regulator_dev *);
int (* set_current_limit) (struct regulator_dev *,int min_uA, int max_uA);
int (* get_current_limit) (struct regulator_dev *);
int (* set_input_current_limit) (struct regulator_dev *, int lim_uA);
int (* set_over_current_protection) (struct regulator_dev *);
int (* set_active_discharge) (struct regulator_dev *, bool enable);
int (* enable) (struct regulator_dev *);
int (* disable) (struct regulator_dev *);
int (* is_enabled) (struct regulator_dev *);
int (* set_mode) (struct regulator_dev *, unsigned int mode);
unsigned int (* get_mode) (struct regulator_dev *);
int (* enable_time) (struct regulator_dev *);
int (* set_ramp_delay) (struct regulator_dev *, int ramp_delay);
int (* set_voltage_time_sel) (struct regulator_dev *,unsigned int old_selector,unsigned int new_selector);
int (* set_soft_start) (struct regulator_dev *);
int (* get_status) (struct regulator_dev *);
unsigned int (* get_optimum_mode) (struct regulator_dev *, int input_uV,int output_uV, int load_uA);
int (* set_load) (struct regulator_dev *, int load_uA);
int (* set_bypass) (struct regulator_dev *dev, bool enable);
int (* get_bypass) (struct regulator_dev *dev, bool *enable);
int (* set_suspend_voltage) (struct regulator_dev *, int uV);
int (* set_suspend_enable) (struct regulator_dev *);
int (* set_suspend_disable) (struct regulator_dev *);
int (* set_suspend_mode) (struct regulator_dev *, unsigned int mode);
int (* set_pull_down) (struct regulator_dev *);
};
MEMBERS
list_voltage
Return one of the supported voltages, in microvolts; zero if the selector indicates a
voltage that is unusable on this system; or negative errno. Selectors range from zero
to one less than regulator_desc.n_voltages. Voltages may be reported in any order.
set_voltage
Set the voltage for the regulator within the range specified. The driver should select
the voltage closest to min_uV.
map_voltage
Convert a voltage into a selector
set_voltage_sel
Set the voltage for the regulator using the specified selector.
get_voltage
Return the currently configured voltage for the regulator.
get_voltage_sel
Return the currently configured voltage selector for the regulator.
set_current_limit
Configure a limit for a current-limited regulator. The driver should select the
current closest to max_uA.
get_current_limit
Get the configured limit for a current-limited regulator.
set_input_current_limit
Configure an input limit.
set_over_current_protection
Support capability of automatically shutting down when detecting an over current
event.
set_active_discharge
Set active discharge enable/disable of regulators.
enable
Configure the regulator as enabled.
disable
Configure the regulator as disabled.
is_enabled
Return 1 if the regulator is enabled, 0 if not. May also return negative errno.
set_mode
Set the configured operating mode for the regulator.
get_mode
Get the configured operating mode for the regulator.
enable_time
Time taken for the regulator voltage output voltage to stabilise after being enabled,
in microseconds.
set_ramp_delay
Set the ramp delay for the regulator. The driver should select ramp delay equal to or
less than(closest) ramp_delay.
set_voltage_time_sel
Time taken for the regulator voltage output voltage to stabilise after being set to a
new value, in microseconds. The function provides the from and to voltage selector,
the function should return the worst case.
set_soft_start
Enable soft start for the regulator.
get_status
Return actual (not as-configured) status of regulator, as a REGULATOR_STATUS value (or
negative errno)
get_optimum_mode
Get the most efficient operating mode for the regulator when running with the
specified parameters.
set_load
Set the load for the regulator.
set_bypass
Set the regulator in bypass mode.
get_bypass
Get the regulator bypass mode state.
set_suspend_voltage
Set the voltage for the regulator when the system is suspended.
set_suspend_enable
Mark the regulator as enabled when the system is suspended.
set_suspend_disable
Mark the regulator as disabled when the system is suspended.
set_suspend_mode
Set the operating mode for the regulator when the system is suspended.
set_pull_down
Configure the regulator to pull down when the regulator is disabled.
DESCRIPTION
This struct describes regulator operations which can be implemented by regulator chip
drivers.
AUTHORS
Liam Girdwood <lrg AT slimlogic.uk>
Author.
Mark Brown <broonie AT opensource.com>
Wolfson Microelectronics,
Author.
COPYRIGHT
Kernel Hackers Manual 4.8. January 2017 STRUCT REGULATOR_OPS(9)
|